@article{oai:toyama.repo.nii.ac.jp:00006554, author = {赤丸, 悟士 and 原, 正憲 and 松山, 政夫}, journal = {富山大学水素同位体科学研究センター研究報告}, month = {May}, note = {application/pdf, We evaluated the electrical resistivity of Pd hydride without electrical contact. An alternating current susceptometer was used to measure the electrical resistivity. When columnar samples were used, it was possible to determine their relative electrical resistivity was obtained after simple analysis. The relative electrical resistivity increased monotonically with increasing hydrogen concentration in the Pd rod. At lower hydrogen concentrations, the obtained relative electrical resistivity was approximately the same as that reported previously, indicating that the alternating-current susceptometer correctly measured relative electrical resistivity. At higher hydrogen concentrations, the results differed from the values reported previously. Sample shape and geometry must be considered to obtain accurate values at higher hydrogen concentrations., Article, 富山大学水素同位体科学研究センター研究報告, 32巻, 2013.05.31, pp.45-53}, pages = {45--53}, title = {交流磁束計を用いたPd 水素化物の電気抵抗測定}, volume = {32}, year = {2013} }