{"created":"2023-07-25T09:07:59.412909+00:00","id":6465,"links":{},"metadata":{"_buckets":{"deposit":"afa8c6e0-ff0e-41fa-8d62-1de6878500ba"},"_deposit":{"created_by":3,"id":"6465","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"6465"},"status":"published"},"_oai":{"id":"oai:toyama.repo.nii.ac.jp:00006465","sets":["663:777:778:798:800"]},"author_link":["22374","22375","22368","22376","22372","22371","22370","22367","22369","22373"],"item_3_alternative_title_19":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Examination of Tritium Retention in Boron-Coated Graphite by Beta-Ray-Induced X-ray Spectrometry"}]},"item_3_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2000","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"62","bibliographicPageStart":"53","bibliographicVolumeNumber":"20","bibliographic_titles":[{"bibliographic_title":"富山大学水素同位体科学研究センター研究報告 = Annual Report of Hydrogen Isotope Research Center, Toyama University"}]}]},"item_3_description_15":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_3_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Tritium retention in boron-coated graphite (B/Graphite) irradiated with tritium ions at room temperature and at high temperatures was examined by beta-ray-induced X-ray spectrometry (BIXS). The results of analyses by X-ray diffraction and X-ray photoelectron spectroscopy for an unirradiated sample suggested that boron coated on the graphite surface formed an amorphous structure and that it contained impurities such as oxygen and carbon. Both a sharp intense peak and a broad weak peak induced by beta-rays appeared in the observed X-ray spectra. It was seen from the X-ray spectra that most of tritium implanted into the B/Graphite at room temperature was retained on the surface and in subsurface layers. In addition, it was seen that the implanted tritium can be easily removed at a relatively low temperature and that the retention amount decreased to 1/3 by heating at 300゜C for 30 min. However, a considerable increase in tritium retention was observed when the irradiation temperature was increased to more than 300C, indicating adsorption of tritium on the bare surface graphite.","subitem_description_type":"Abstract"}]},"item_3_description_40":{"attribute_name":"資源タイプ(DSpace)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_3_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"22372","nameIdentifierScheme":"WEKO"}],"names":[{"name":"MATSUYAMA, Masao"}]},{"nameIdentifiers":[{"nameIdentifier":"22373","nameIdentifierScheme":"WEKO"}],"names":[{"name":"MURAI, Tadayuki"}]},{"nameIdentifiers":[{"nameIdentifier":"22374","nameIdentifierScheme":"WEKO"}],"names":[{"name":"WATANABE, Kuniaki"}]},{"nameIdentifiers":[{"nameIdentifier":"22375","nameIdentifierScheme":"WEKO"}],"names":[{"name":"TSUZUKI, Kazuhiro"}]},{"nameIdentifiers":[{"nameIdentifier":"22376","nameIdentifierScheme":"WEKO"}],"names":[{"name":"NODA, Nobuaki"}]}]},"item_3_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.15099/00006459","subitem_identifier_reg_type":"JaLC"}]},"item_3_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"富山大学水素同位体科学研究センター"}]},"item_3_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11841872","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0916-8486","subitem_source_identifier_type":"ISSN"}]},"item_3_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"松山, 政夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"村井, 忠幸"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"渡辺, 国昭"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"都築, 和泰"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"野田, 信明"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-17"}],"displaytype":"detail","filename":"annual_report20-6.pdf","filesize":[{"value":"529.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"annual_report20-6.pdf","url":"https://toyama.repo.nii.ac.jp/record/6465/files/annual_report20-6.pdf"},"version_id":"82e2f7bf-fc6f-4c6d-9dd6-d4869debc496"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"β線誘起X線計測法による硼素コーティング黒鉛材料のトリチウム保持に関する検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"β線誘起X線計測法による硼素コーティング黒鉛材料のトリチウム保持に関する検討"}]},"item_type_id":"3","owner":"3","path":["800"],"pubdate":{"attribute_name":"公開日","attribute_value":"2007-10-03"},"publish_date":"2007-10-03","publish_status":"0","recid":"6465","relation_version_is_last":true,"title":["β線誘起X線計測法による硼素コーティング黒鉛材料のトリチウム保持に関する検討"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-07-25T15:41:44.186297+00:00"}