{"created":"2023-07-25T09:06:15.190318+00:00","id":4473,"links":{},"metadata":{"_buckets":{"deposit":"5fc3e55e-c711-4505-bd34-44a4e5ffe8f5"},"_deposit":{"created_by":3,"id":"4473","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"4473"},"status":"published"},"_oai":{"id":"oai:toyama.repo.nii.ac.jp:00004473","sets":["496:556:559:560:605"]},"author_link":["57775","57769","57774","57776","57772","57773","57770","57771"],"item_3_alternative_title_19":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Electric charge measurements of snow fragments and rain drops and a consideration of electric structure of clouds in winter"}]},"item_3_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1994-02","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"22","bibliographicPageStart":"15","bibliographicVolumeNumber":"45","bibliographic_titles":[{"bibliographic_title":"富山大学工学部紀要"}]}]},"item_3_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"It is very important for electric power transmission line to protect the electric surge due to lightening. It is therefore indespensable to forecast the lightening. The measurement of the electric charge of snow fragments and rain dorops is intended for examining the relations of the electric charge of them, the snow falling and the lightening. It is carried out successively by a simple method which consists of an accumulating metal plate of the snow fragments on the porcelain insulator column and a high sensitive electrometer. It is found from the measurements that snow fragments with both electric polarities fall down alternatively and the almost same charge fall down in one falling period. A simple theory of lightening in winter is proposed based on the charge measurements.","subitem_description_type":"Abstract"},{"subitem_description":"電力送電線にとって雷撃による電気的サージを防ぐことは非常に大切である。それ故,雷撃の予測は不可欠である。降雪の電気量,降雪と雷撃の関係を調べるために,降雪の荷電量の測定を意図した。これは簡単な方法により,成功裡に行われた。この方法は長幹碍子の上に乗せた雪を集める金属板と高感度のエレクトロメータから構成されている。これらの測定から,両方の電気的極性をもつ雪が交互に降って来ることおよび一回の降雪の間にほぼ等量の電荷が降りて来ることが分った。これらの電荷測定にもとずき,冬季雷撃に関する簡単な理論を提案する。","subitem_description_type":"Abstract"}]},"item_3_description_40":{"attribute_name":"資源タイプ(DSpace)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_3_description_6":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"富山大学工学部紀要,45, Page 15-22","subitem_description_type":"Other"}]},"item_3_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"57773","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kitamura, Iwao"}]},{"nameIdentifiers":[{"nameIdentifier":"57774","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Sakumoto, Norihiro"}]},{"nameIdentifiers":[{"nameIdentifier":"57775","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Minamiguchi, Yoshifumi"}]},{"nameIdentifiers":[{"nameIdentifier":"57776","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Ikeda, Nagayasu"}]}]},"item_3_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.15099/00004467","subitem_identifier_reg_type":"JaLC"}]},"item_3_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"富山大学工学部"}]},"item_3_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00175872","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03871339","subitem_source_identifier_type":"ISSN"}]},"item_3_subject_22":{"attribute_name":"国立国会図書館分類","attribute_value_mlt":[{"subitem_subject":"ZM2","subitem_subject_scheme":"NDLC"}]},"item_3_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"北村, 岩雄"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"作本, 憲大"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"南口, 芳文"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"池田, 長康"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-16"}],"displaytype":"detail","filename":"Kokiyo_45_01_Page015to022.pdf","filesize":[{"value":"4.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Kokiyo_45_01_Page015to022.pdf","url":"https://toyama.repo.nii.ac.jp/record/4473/files/Kokiyo_45_01_Page015to022.pdf"},"version_id":"d4bcb7ee-44e5-49c7-aea1-7b6def2b93b9"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"降雪","subitem_subject_scheme":"Other"},{"subitem_subject":"降雨","subitem_subject_scheme":"Other"},{"subitem_subject":"電化量測定","subitem_subject_scheme":"Other"},{"subitem_subject":"冬季雷雲","subitem_subject_scheme":"Other"},{"subitem_subject":"冬季雷雲の電気構造","subitem_subject_scheme":"Other"},{"subitem_subject":"停電事故","subitem_subject_scheme":"Other"},{"subitem_subject":"冬季降雪","subitem_subject_scheme":"Other"},{"subitem_subject":"電気的サージ","subitem_subject_scheme":"Other"},{"subitem_subject":"冬季雷撃","subitem_subject_scheme":"Other"},{"subitem_subject":"雷","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"降雪,降雨の電化量測定と冬季雷雲の電気構造に関する考察","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"降雪,降雨の電化量測定と冬季雷雲の電気構造に関する考察"}]},"item_type_id":"3","owner":"3","path":["605"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-10-12"},"publish_date":"2012-10-12","publish_status":"0","recid":"4473","relation_version_is_last":true,"title":["降雪,降雨の電化量測定と冬季雷雲の電気構造に関する考察"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-25T15:07:58.184546+00:00"}