@article{oai:toyama.repo.nii.ac.jp:00004272, author = {宮下, 尚 and 塩見, 裕 and 中村, 明夫}, journal = {富山大学工学部紀要}, month = {Mar}, note = {application/pdf, An experimental investigation was performed to study the mass transfer in an annular, as the first step of the heat transfer in non-coaxial double tube for the purposes of the safety in nuclear reactors and the improvement of heat exchangers. Mass transfer coefficients between a flowing solution and the inside tube wall in annular were measured using an electrochemical method by wean of the redox reaction of ferricyanide/ferrocyanide couple. The Reynolds number was varied from 1,300 to 40,000 with six kinds of Schmidt number and three kinds of the retio of inner and outer tube diameters in an experimental condition. The correlation of mass transfer data in annuli was expressed as follows: Sh=0.015(Re)^<0.8>(Sc)^<0.4>(Do/Di)^<0.53> This is reasonably agreed with previous heat transfer correlations by mean of the analogy for heat and mass transfer., 近年,原子炉の炉心を想定した二重管の伝熱に関する研究が混相流の伝熱,沸騰伝熱を含め活発に行われるようになってきた。 二重管の環状部流れにおける伝熱は古くから研究が行われており,多くの研究者によって相関式が報告されている。 しかしそれらの間には,操作条件によってかなりの相異があり,統一的な報告はないようである。 本研究では,原子炉の安全性に対する考慮もさることながら熱交換器の改良などを目的とした偏心二重管(たわみ二重管)内流れの伝熱を究明する基礎段階として,同心二重管環状部の内管壁と高シュミット数流体間の物質移動係数を電極反応を用いて測定し,操作変数(Re数,Sc数)および装置変数(管径比)を数種変え相聞を行なった。 そして従来の熱および物質移動のアナロジーから既往の伝熱実験と比較し検討を加えた。, Article, 富山大学工学部紀要,32, 44-48.(1981)}, pages = {44--48}, title = {共軸二重管の環状部流れにおける内管壁 : 流体間物質移動}, volume = {32}, year = {1981} }