{"created":"2023-07-25T09:05:42.047788+00:00","id":3818,"links":{},"metadata":{"_buckets":{"deposit":"00d5d119-b134-404a-99d6-1fc784b35228"},"_deposit":{"created_by":3,"id":"3818","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"3818"},"status":"published"},"_oai":{"id":"oai:toyama.repo.nii.ac.jp:00003818","sets":["496:556:559:560:573"]},"author_link":["54925","54924"],"item_3_alternative_title_19":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Influences of Some Conditions on the Electrolysis in Chlorate Cell"}]},"item_3_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1962-03-20","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1/2","bibliographicPageEnd":"72","bibliographicPageStart":"67","bibliographicVolumeNumber":"13","bibliographic_titles":[{"bibliographic_title":"富山大学工学部紀要"}]}]},"item_3_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Experiments on the influences of the current density at anode, the current concentration, and the concentration of hypochlorous acid on the electrolysis in chlorate cell had been conducted. The results were in accord with the writer's theory. Calculation about the buffer action of the chromate added to inhibit cathodic reduction was conducted.","subitem_description_type":"Abstract"},{"subitem_description":"若干の条件がクロレート槽の電解状況に及ぼす影響を実験したところ別報の推論と定性的或いは定量的に一致したので報告する。\nなお,陰極還元防止剤のp^H緩衝作用につき計算した。","subitem_description_type":"Abstract"}]},"item_3_description_40":{"attribute_name":"資源タイプ(DSpace)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_3_description_6":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"富山大学工学部紀要,13(1/2)","subitem_description_type":"Other"}]},"item_3_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"54925","nameIdentifierScheme":"WEKO"}],"names":[{"name":"YOKOYAMA, Tatsuo"}]}]},"item_3_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.15099/00003812","subitem_identifier_reg_type":"JaLC"}]},"item_3_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"富山大学工学部"}]},"item_3_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00175872","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03871339","subitem_source_identifier_type":"ISSN"}]},"item_3_subject_22":{"attribute_name":"国立国会図書館分類","attribute_value_mlt":[{"subitem_subject":"ZM2","subitem_subject_scheme":"NDLC"}]},"item_3_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"横山, 辰雄"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-16"}],"displaytype":"detail","filename":"Kokiyo_13_01_Page067to072.pdf","filesize":[{"value":"13.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Kokiyo_13_01_Page067to072.pdf","url":"https://toyama.repo.nii.ac.jp/record/3818/files/Kokiyo_13_01_Page067to072.pdf"},"version_id":"81037c63-9b9e-4cb7-971e-7e740f2db43b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"クロレート槽","subitem_subject_scheme":"Other"},{"subitem_subject":"電解状況","subitem_subject_scheme":"Other"},{"subitem_subject":"諸種条件","subitem_subject_scheme":"Other"},{"subitem_subject":"陰極還元防止剤","subitem_subject_scheme":"Other"},{"subitem_subject":"pH緩衝作用","subitem_subject_scheme":"Other"},{"subitem_subject":"陽極電流密度","subitem_subject_scheme":"Other"},{"subitem_subject":"電流濃度","subitem_subject_scheme":"Other"},{"subitem_subject":"p^H緩衝作用","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"クロレート槽の電解状況に及ぼす諸種条件の影響","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"クロレート槽の電解状況に及ぼす諸種条件の影響"}]},"item_type_id":"3","owner":"3","path":["573"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-09-19"},"publish_date":"2012-09-19","publish_status":"0","recid":"3818","relation_version_is_last":true,"title":["クロレート槽の電解状況に及ぼす諸種条件の影響"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-25T15:15:38.337141+00:00"}