{"created":"2023-07-25T09:05:25.670484+00:00","id":3469,"links":{},"metadata":{"_buckets":{"deposit":"6ae184de-50b9-48fd-b138-aa0ccc91f8c5"},"_deposit":{"created_by":3,"id":"3469","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"3469"},"status":"published"},"_oai":{"id":"oai:toyama.repo.nii.ac.jp:00003469","sets":["496:556:559:560:563"]},"author_link":["53347","53346"],"item_3_alternative_title_19":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Dynamical Tester for Small Loads"}]},"item_3_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1951-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"10","bibliographicPageStart":"9","bibliographicVolumeNumber":"3","bibliographic_titles":[{"bibliographic_title":"富山大学工学部紀要"}]}]},"item_3_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"There are many pressure gauges of statical type, but dynamical tester for light pressure or small loads are very few. We had to measure the contact pressure of the relay, and hence, one device has been made by the use of the quarz crystal oscillator whose frequency shows the very small variations with the pressure between the electrodes.","subitem_description_type":"Abstract"}]},"item_3_description_40":{"attribute_name":"資源タイプ(DSpace)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_3_description_6":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"富山大学工学部紀要,3(1),1951-12, Page 9-10","subitem_description_type":"Other"}]},"item_3_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"53347","nameIdentifierScheme":"WEKO"}],"names":[{"name":"INOUE, Hirosi"}]}]},"item_3_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.15099/00003463","subitem_identifier_reg_type":"JaLC"}]},"item_3_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"富山大学工学部"}]},"item_3_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00175872","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03871339","subitem_source_identifier_type":"ISSN"}]},"item_3_subject_22":{"attribute_name":"国立国会図書館分類","attribute_value_mlt":[{"subitem_subject":"ZM2","subitem_subject_scheme":"NDLC"}]},"item_3_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"井上, 浩"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-16"}],"displaytype":"detail","filename":"Kokiyo_3_01_Page009to010.pdf","filesize":[{"value":"1.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Kokiyo_3_01_Page009to010.pdf","url":"https://toyama.repo.nii.ac.jp/record/3469/files/Kokiyo_3_01_Page009to010.pdf"},"version_id":"658074cc-ca87-4e88-95bd-142b9dec6de0"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"圧力測定器","subitem_subject_scheme":"Other"},{"subitem_subject":"動的軽圧力測定器","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"動的軽圧力測定器の一案","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"動的軽圧力測定器の一案"}]},"item_type_id":"3","owner":"3","path":["563"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-07-24"},"publish_date":"2012-07-24","publish_status":"0","recid":"3469","relation_version_is_last":true,"title":["動的軽圧力測定器の一案"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-25T15:20:14.113046+00:00"}