@article{oai:toyama.repo.nii.ac.jp:00003455, author = {酒井, 信之}, issue = {1}, journal = {富山大學工学部高岡工業專門学校紀要}, month = {Dec}, note = {One of the studies shout liquid spray, investigation of result of liquid discharge quantity through the given nozzle is reported, and which is consist of both experimentally measured and theoretically calculated. These conclusions are compared with each other and determined the coefficient of discharge of liquid through the given nozzle. Liquid spray is made by means of pressure spray apparatus, consist of pressure gas bombe (200 atm.), liquid holder(30l water tank)and nozzle etc. In this experiment, several types of nozzle and guide is used,and discharge pressure is varied from 2 to 25 atm. (gauge)., 噴孔を用い液体を高圧下で噴出せしめ,微粒化することは既に内燃機関,気泡による液体の撹拌,液体混合,噴霧池による液体の冷却,噴霧乾燥その他多数利用されている。 本報は噴孔による液体の流出実験として,水を種々の噴孔を用いて噴出させ,噴霧圧力と流出量の関係を調べ,更に理論的流出量を計算し,各々の場合について流量係数をもとめて,ノッズル及びガイドの性質を調べたものである。, Article, 富山大學工学部高岡工業專門学校紀要,2(1),1950-12, Page 34-39}, pages = {34--39}, title = {噴孔による液体の流出実驗}, volume = {2}, year = {1950} }