{"created":"2023-07-25T09:04:25.791134+00:00","id":2267,"links":{},"metadata":{"_buckets":{"deposit":"13e8424d-308c-448a-b6f4-2c9b2f518d15"},"_deposit":{"created_by":3,"id":"2267","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"2267"},"status":"published"},"_oai":{"id":"oai:toyama.repo.nii.ac.jp:00002267","sets":["439:440:441:442"]},"author_link":["153988","6175","153985","153986","153982","153989","153979","153978","153980","153984","153983"],"item_2_alternative_title_19":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"A New Thermal Diffusion Flow Probe for Continuous Monitoring of Cerebral Blood Flow in Small Animals"}]},"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1989-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"12","bibliographicPageEnd":"1084","bibliographicPageStart":"1078","bibliographicVolumeNumber":"29","bibliographic_titles":[{"bibliographic_title":"Neurologia medico-chirurgica : 神経外科"}]}]},"item_2_description_15":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The Peltier stack, which allows quantitative measurement of cerebral blood flow (CBF) by means of thermal diffusion, has a probe too large for use in small animals. However, it is difficult to measure CBF by a thermal diffusion method involving the use of a constantan heating wire, because of heat conduction between the two gold plates. The authors developed a new thermal diffusion flow probe, using a constantan wire as a heat source rather than the Peltier stack. With the new probe, separation of the gold plates and attachment of a pair of long thermocouples minimize heat conduction between the two plates. Moreover, the probe itself is considerably, smaller than that of the Peltier stack. The new probe was inserted to the subdural space of rabbits and the voltage (V; mV) was measured with an amplifier by the circuit of constant current method. CBF (F; ml/100 g/min) was measured simultaneously by the hydrogen clearance method in the adjacent cortex. A regression equation of F=29,111 (1/V-1/226) was obtained between 35 pairs of F and V (r=0.92, p < 0.001), which verified that CBF can be accurately measured with the new probe","subitem_description_type":"Abstract"}]},"item_2_description_40":{"attribute_name":"資源タイプ(DSpace)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_2_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"153984","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kuwayama, Naoya"}]},{"nameIdentifiers":[{"nameIdentifier":"153985","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Fukuda, Osamu"}]},{"nameIdentifiers":[{"nameIdentifier":"153986","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Koshu, Keiji"}]},{"nameIdentifiers":[{"nameIdentifier":"6175","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"1000070125269","nameIdentifierScheme":"CiNii ID","nameIdentifierURI":"http://ci.nii.ac.jp/nrid/1000070125269"},{"nameIdentifier":"70125269","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://nrid.nii.ac.jp/nrid/1000070125269"}],"names":[{"name":"Endo, Shunro"}]},{"nameIdentifiers":[{"nameIdentifier":"153988","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Saito, Tateo"}]},{"nameIdentifiers":[{"nameIdentifier":"153989","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Takaku, Akira"}]}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本脳神経外科学会"}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"rights: 本文データは日本脳神経外科学会の許諾に基づきCiNiiから複製したものである"}]},"item_2_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00358613","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"4708105","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"桑山, 直也"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"福田, 修"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"甲州, 啓二"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"遠藤, 俊郎"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"斉藤, 建夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"高久, 晃"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-15"}],"displaytype":"detail","filename":"shinkeigeka89-1078.pdf","filesize":[{"value":"704.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"shinkeigeka89-1078.pdf","url":"https://toyama.repo.nii.ac.jp/record/2267/files/shinkeigeka89-1078.pdf"},"version_id":"6c633bf3-b373-4ee1-a6f4-a8b9c5c9ce99"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"cerebral blood flow","subitem_subject_scheme":"Other"},{"subitem_subject":"heat clearance method","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"改良型熱拡散センサーによる定量的局所脳血流量測定法 : 特に小動物を対象とした測定法の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"改良型熱拡散センサーによる定量的局所脳血流量測定法 : 特に小動物を対象とした測定法の開発"}]},"item_type_id":"2","owner":"3","path":["442"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-01-31"},"publish_date":"2008-01-31","publish_status":"0","recid":"2267","relation_version_is_last":true,"title":["改良型熱拡散センサーによる定量的局所脳血流量測定法 : 特に小動物を対象とした測定法の開発"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-07-25T13:55:09.524661+00:00"}