{"created":"2023-07-25T09:15:51.425025+00:00","id":15883,"links":{},"metadata":{"_buckets":{"deposit":"fdb47d0e-5730-48fb-abd4-b7024f92e67a"},"_deposit":{"created_by":19,"id":"15883","owners":[19],"pid":{"revision_id":0,"type":"depid","value":"15883"},"status":"published"},"_oai":{"id":"oai:toyama.repo.nii.ac.jp:00015883","sets":["496:556:557:558"]},"author_link":["168118","168119","168117","5950","14233","41305","168110","168115","168116"],"item_2_alternative_title_19":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Involuntary Measurement System for Respiratory Waveform for Prevention of Accidental Drowning during Bathing"}]},"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"24","bibliographicPageStart":"17","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"Advanced Biomedical Engineering"},{"bibliographic_title":"ABE"}]}]},"item_2_description_15":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Death rate of accidental drowning in the bathtub was the highest among casualties occurring at home, according to the annual report of the Japanese Ministry of Health, Labour and Welfare in 2007. To prevent accidental drowning during bathing at home, we obtained respiratory waveforms from bioelectric impedance (BEI) measurement using non-contact electrodes. The BEI measurement is an involuntary measurement method, from which respiratory waveform during bathing can be extracted. In the present study, to find the most appropriate electrode configuration as well as the optimal measuring frequency, we calculated the frequency dependence of impedance amplitude by numerical technique based on a three-dimensional finite difference method for a composite system consisting of a human body submerged in bath water. The results of model calculation agreed with the experimental results. Next, to obtain respiratory waveforms with large amplitudes, we investigated the optimal frequency experimentally. The frequency of 1MHz was suitable for involuntary measurement of respiratory waveform during bathing.","subitem_description_type":"Abstract"}]},"item_2_description_40":{"attribute_name":"資源タイプ(DSpace)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_2_description_6":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Advanced Biomedical Engineering 2, 17-24.(2013)","subitem_description_type":"Other"}]},"item_2_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Japanese Society for Medical and Biological Engineering"},{"subitem_publisher":"一般社団法人日本生体医工学会"}]},"item_2_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.14326/abe.2.17","subitem_relation_type_select":"DOI"}}]},"item_2_relation_14":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"J-STAGE"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/article/abe/2/0/2_17/_article/-char/ja/","subitem_relation_type_select":"URI"}}]},"item_2_relation_29":{"attribute_name":"論文ID(NAID)","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"130004568017","subitem_relation_type_select":"NAID"}}]},"item_2_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(C) 2013, JAPANESE SOCIETY FOR MEDICAL AND BIOLOGICAL ENGINEERING"}]},"item_2_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2187-5219","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nakajima, Kazuki"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Sekine, Katsuhisa"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Yamazaki, Katsuya"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Tanpo, Atsushi"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Tsubosaka, Yasushi"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Kim, Juhyon"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Tobe, Kazuyuki"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Kobayashi, Masashi"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Sasaki, Kazuo"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-03-27"}],"displaytype":"detail","filename":"AdvBioEng_2_17to24_Kim.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AdvBioEng_2_17to24_Kim","url":"https://toyama.repo.nii.ac.jp/record/15883/files/AdvBioEng_2_17to24_Kim.pdf"},"version_id":"479d22a2-b408-4257-a7d4-02a6a2c77681"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"bathing","subitem_subject_scheme":"Other"},{"subitem_subject":"respiratory waveform","subitem_subject_scheme":"Other"},{"subitem_subject":"bioelectric impedance","subitem_subject_scheme":"Other"},{"subitem_subject":"involuntary measurement","subitem_subject_scheme":"Other"},{"subitem_subject":"bathing","subitem_subject_scheme":"Other"},{"subitem_subject":"respiratory waveform","subitem_subject_scheme":"Other"},{"subitem_subject":"bioelectric impedance","subitem_subject_scheme":"Other"},{"subitem_subject":"involuntary measurement","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Involuntary Measurement System for Respiratory Waveform for Prevention of Accidental Drowning during Bathing","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Involuntary Measurement System for Respiratory Waveform for Prevention of Accidental Drowning during Bathing"},{"subitem_title":"Involuntary Measurement System for Respiratory Waveform for Prevention of Accidental Drowning during Bathing","subitem_title_language":"en"}]},"item_type_id":"2","owner":"19","path":["558"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-03-27"},"publish_date":"2018-03-27","publish_status":"0","recid":"15883","relation_version_is_last":true,"title":["Involuntary Measurement System for Respiratory Waveform for Prevention of Accidental Drowning during Bathing"],"weko_creator_id":"19","weko_shared_id":-1},"updated":"2023-07-25T14:06:52.767718+00:00"}