{"_buckets": {"deposit": "b30a83dd-9ea8-4d1e-ac05-ec7f8430b79e"}, "_deposit": {"created_by": 3, "id": "6334", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "6334"}, "status": "published"}, "_oai": {"id": "oai:toyama.repo.nii.ac.jp:00006334", "sets": ["783"]}, "author_link": ["59200", "59205", "59195", "59204", "59198", "10472", "59196", "59206", "59201", "59202", "59203", "59199"], "item_3_alternative_title_19": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Contamination of Ionization Chambers Exposed to Tritium Gas and Tritiated Water - Cu, Ni-plated, and Au-plated Chambers -"}]}, "item_3_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1984", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "22", "bibliographicPageStart": "13", "bibliographicVolumeNumber": "4", "bibliographic_titles": [{"bibliographic_title": "富山大学トリチウム科学センター研究報告 = Annual Report of Tritium Research Center, Toyama University"}]}]}, "item_3_description_15": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_3_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Ionization chambers are widely used for measuring tritium in the gas phase. Recently, however, it has been perceived that the contamination of the chamber wall due to the adsorption of tritium significantly impairs the reliability of the ionization chambers when they are used for measuring tritium at high concentrations. As a first step to overcome this difficulty, we studied the contamination of ionization chambers with tritium gas (HT) and/or tritiated water vapor (HTO) by using different component materials (Cu, Ni-plated, and Au-plated chambers). In case of the Cu chamber, the concentration of tritium gas in the chamber decreased exponentially with time due to purge by fresh air to a certain level. Then, the decrease rate slowed down drastically (the memory effect). This is caused by adsorption of tritiated water on the surface of the material; the tritiated water being formed in the chamber due to exchange reaction with water vapor. In case of the Ni-plated chamber, the memory effect was also observed; however, this is not due to the adsorbed tritiated water. Instead, it is thought to due to adsorbed tritium such as T(a) or HT(a). With respect to the Au-plated chamber, no memory effect took place when it was exposed to tritium gas (HT). On the other hand, when the chambers were exposed to tritiated water vapor, all showed a large memory effect. It was clarified that the memory effect principally arose from the physically adsorbed tritiated water. In conclusion, the Au-plated chamber is most preferable for measuring tritium gas. However, the memory effect due to the adsorption of tritiated water vapor is as large as that for the other two. Therefore, it is necessary to develop suitable decontamination methods for the contamination will have to be avoided by the selection of more suitable materials.", "subitem_description_type": "Abstract"}]}, "item_3_description_40": {"attribute_name": "資源タイプ(DSpace)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_3_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "59201", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Watanabe, Kuniaki"}]}, {"nameIdentifiers": [{"nameIdentifier": "59202", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kato, Kazuma"}]}, {"nameIdentifiers": [{"nameIdentifier": "59203", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Matsuyama, Masao"}]}, {"nameIdentifiers": [{"nameIdentifier": "59204", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Miyake, Hitoshi"}]}, {"nameIdentifiers": [{"nameIdentifier": "59205", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Sato, Hiroo"}]}, {"nameIdentifiers": [{"nameIdentifier": "59206", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Maekawa, Hiroshi"}]}]}, "item_3_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.15099/00006328", "subitem_identifier_reg_type": "JaLC"}]}, "item_3_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "富山大学トリチウム科学センター"}]}, "item_3_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10100133", "subitem_source_identifier_type": "NCID"}]}, "item_3_source_id_8": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0287-1408", "subitem_source_identifier_type": "ISSN"}]}, "item_3_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "松山, 政夫"}], "nameIdentifiers": [{"nameIdentifier": "59195", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三宅, 均"}], "nameIdentifiers": [{"nameIdentifier": "59196", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "竹越, 栄俊"}], "nameIdentifiers": [{"nameIdentifier": "10472", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "1000000019184", "nameIdentifierScheme": "CiNii ID", "nameIdentifierURI": "http://ci.nii.ac.jp/nrid/1000000019184"}, {"nameIdentifier": "00019184", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000000019184"}]}, {"creatorNames": [{"creatorName": "加藤, 一真"}], "nameIdentifiers": [{"nameIdentifier": "59198", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤, 博夫"}], "nameIdentifiers": [{"nameIdentifier": "59199", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "前川, 寛"}], "nameIdentifiers": [{"nameIdentifier": "59200", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-02-17"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "annual_report4-2.pdf", "filesize": [{"value": "792.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 792200.0, "url": {"label": "annual_report4-2.pdf", "url": "https://toyama.repo.nii.ac.jp/record/6334/files/annual_report4-2.pdf"}, "version_id": "951a772d-018b-4e69-b923-e243348a6e70"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "トリチウムによる電離箱の汚染 : 電離箱材料とトリチウムの化学形", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "トリチウムによる電離箱の汚染 : 電離箱材料とトリチウムの化学形"}]}, "item_type_id": "3", "owner": "3", "path": ["783"], "permalink_uri": "https://doi.org/10.15099/00006328", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-10-03"}, "publish_date": "2007-10-03", "publish_status": "0", "recid": "6334", "relation": {}, "relation_version_is_last": true, "title": ["トリチウムによる電離箱の汚染 : 電離箱材料とトリチウムの化学形"], "weko_shared_id": 3}
トリチウムによる電離箱の汚染 : 電離箱材料とトリチウムの化学形
https://doi.org/10.15099/00006328
https://doi.org/10.15099/000063283eafb532-952b-44ac-b5d4-60a6f4638745
名前 / ファイル | ライセンス | アクション |
---|---|---|
annual_report4-2.pdf (792.2 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-10-03 | |||||
タイトル | ||||||
タイトル | トリチウムによる電離箱の汚染 : 電離箱材料とトリチウムの化学形 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.15099/00006328 | |||||
ID登録タイプ | JaLC | |||||
著者 |
松山, 政夫
× 松山, 政夫× 三宅, 均× 竹越, 栄俊× 加藤, 一真× 佐藤, 博夫× 前川, 寛 |
|||||
著者別名 | ||||||
姓名 | Watanabe, Kuniaki | |||||
著者別名 | ||||||
姓名 | Kato, Kazuma | |||||
著者別名 | ||||||
姓名 | Matsuyama, Masao | |||||
著者別名 | ||||||
姓名 | Miyake, Hitoshi | |||||
著者別名 | ||||||
姓名 | Sato, Hiroo | |||||
著者別名 | ||||||
姓名 | Maekawa, Hiroshi | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | Contamination of Ionization Chambers Exposed to Tritium Gas and Tritiated Water - Cu, Ni-plated, and Au-plated Chambers - | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Ionization chambers are widely used for measuring tritium in the gas phase. Recently, however, it has been perceived that the contamination of the chamber wall due to the adsorption of tritium significantly impairs the reliability of the ionization chambers when they are used for measuring tritium at high concentrations. As a first step to overcome this difficulty, we studied the contamination of ionization chambers with tritium gas (HT) and/or tritiated water vapor (HTO) by using different component materials (Cu, Ni-plated, and Au-plated chambers). In case of the Cu chamber, the concentration of tritium gas in the chamber decreased exponentially with time due to purge by fresh air to a certain level. Then, the decrease rate slowed down drastically (the memory effect). This is caused by adsorption of tritiated water on the surface of the material; the tritiated water being formed in the chamber due to exchange reaction with water vapor. In case of the Ni-plated chamber, the memory effect was also observed; however, this is not due to the adsorbed tritiated water. Instead, it is thought to due to adsorbed tritium such as T(a) or HT(a). With respect to the Au-plated chamber, no memory effect took place when it was exposed to tritium gas (HT). On the other hand, when the chambers were exposed to tritiated water vapor, all showed a large memory effect. It was clarified that the memory effect principally arose from the physically adsorbed tritiated water. In conclusion, the Au-plated chamber is most preferable for measuring tritium gas. However, the memory effect due to the adsorption of tritiated water vapor is as large as that for the other two. Therefore, it is necessary to develop suitable decontamination methods for the contamination will have to be avoided by the selection of more suitable materials. | |||||
書誌情報 |
富山大学トリチウム科学センター研究報告 = Annual Report of Tritium Research Center, Toyama University 巻 4, p. 13-22, 発行日 1984 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0287-1408 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10100133 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 富山大学トリチウム科学センター | |||||
資源タイプ(DSpace) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article |