WEKO3
アイテム
{"_buckets": {"deposit": "97ac5936-9e09-4993-a6fd-704157f34e3b"}, "_deposit": {"created_by": 3, "id": "6315", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "6315"}, "status": "published"}, "_oai": {"id": "oai:toyama.repo.nii.ac.jp:00006315", "sets": ["781"]}, "author_link": ["59321", "59322", "59325", "59324", "59329", "59326", "59334", "59332", "59335", "59336", "59323", "59331", "59327", "59330", "59328", "59333"], "item_3_alternative_title_19": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Clean-up Capability of an Emergency Detritiation System (II)"}]}, "item_3_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1982", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "26", "bibliographicPageStart": "21", "bibliographicVolumeNumber": "2", "bibliographic_titles": [{"bibliographic_title": "富山大学トリチウム科学センター研究報告 = Annual Report of Tritium Research Center, Toyama University"}]}]}, "item_3_description_15": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_3_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "An emergency tritium removing system, using a precious metal/alumina catalyst, was designed and constructed in order to decontaminate tritium leaked accidentally into laboratory rooms. The performance of thee system was examined using a balloon for helium recovery or an aluminum vessel as a substitute of a laboratory room. Tritium gas containing about 10% tritiated methane (CH3T) as an impurity was introduced into the experimental room and then removed with an air flow rate of 72 m3/h. Tritium gas (T2) was removed satisfactorily, i.e. the reaction probability was unity, due to a Pd/Al2O3 catalyst (Nippon Jun Suiso Co. Ltd) at 200℃, while the tritiated methane could not be removed with a sufficient amount of efficiency: its reaction probability was below unity. It was found that the reaction probability of the tritiated methane became unity above 300℃ for this catalyst. On the basis of these results, it is estimated that the accidental leakage of tritium of 5Ci (which is the maximum permissible amount used in a day in this laboratory) into a laboratory room can be removed within an 18h period.", "subitem_description_type": "Abstract"}]}, "item_3_description_40": {"attribute_name": "資源タイプ(DSpace)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_3_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "59329", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Matsuyama, Masao"}]}, {"nameIdentifiers": [{"nameIdentifier": "59330", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Miyake, Hitoshi"}]}, {"nameIdentifiers": [{"nameIdentifier": "59331", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Ashida, Kan"}]}, {"nameIdentifiers": [{"nameIdentifier": "59332", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Ichimura, Kenji"}]}, {"nameIdentifiers": [{"nameIdentifier": "59333", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Watanabe, Kuniaki"}]}, {"nameIdentifiers": [{"nameIdentifier": "59334", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Takeuchi, Toyosaburo"}]}, {"nameIdentifiers": [{"nameIdentifier": "59335", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kon, Shinji"}]}, {"nameIdentifiers": [{"nameIdentifier": "59336", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Inoue, Teruaki"}]}]}, "item_3_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.15099/00006309", "subitem_identifier_reg_type": "JaLC"}]}, "item_3_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "富山大学トリチウム科学センター"}]}, "item_3_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10100133", "subitem_source_identifier_type": "NCID"}]}, "item_3_source_id_8": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0287-1408", "subitem_source_identifier_type": "ISSN"}]}, "item_3_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "松山, 政夫"}], "nameIdentifiers": [{"nameIdentifier": "59321", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三宅, 均"}], "nameIdentifiers": [{"nameIdentifier": "59322", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "芦田, 完"}], "nameIdentifiers": [{"nameIdentifier": "59323", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "市村, 憲司"}], "nameIdentifiers": [{"nameIdentifier": "59324", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "渡辺, 国昭"}], "nameIdentifiers": [{"nameIdentifier": "59325", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "竹内, 豊三郎"}], "nameIdentifiers": [{"nameIdentifier": "59326", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金, 信次"}], "nameIdentifiers": [{"nameIdentifier": "59327", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "井上, 照明"}], "nameIdentifiers": [{"nameIdentifier": "59328", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-02-17"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "annual_report2-3.pdf", "filesize": [{"value": "496.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 496300.0, "url": {"label": "annual_report2-3.pdf", "url": "https://toyama.repo.nii.ac.jp/record/6315/files/annual_report2-3.pdf"}, "version_id": "b7b4a1f0-2017-433b-8dce-c76028ed8799"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "トリチウム除去装置の性能試験(II)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "トリチウム除去装置の性能試験(II)"}]}, "item_type_id": "3", "owner": "3", "path": ["781"], "permalink_uri": "https://doi.org/10.15099/00006309", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-10-03"}, "publish_date": "2007-10-03", "publish_status": "0", "recid": "6315", "relation": {}, "relation_version_is_last": true, "title": ["トリチウム除去装置の性能試験(II)"], "weko_shared_id": -1}
トリチウム除去装置の性能試験(II)
https://doi.org/10.15099/00006309
https://doi.org/10.15099/000063093eb295ae-4d41-4811-9805-0456d7d01edf
名前 / ファイル | ライセンス | アクション |
---|---|---|
annual_report2-3.pdf (496.3 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-10-03 | |||||
タイトル | ||||||
タイトル | トリチウム除去装置の性能試験(II) | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.15099/00006309 | |||||
ID登録タイプ | JaLC | |||||
著者 |
松山, 政夫
× 松山, 政夫× 三宅, 均× 芦田, 完× 市村, 憲司× 渡辺, 国昭× 竹内, 豊三郎× 金, 信次× 井上, 照明 |
|||||
著者別名 | ||||||
姓名 | Matsuyama, Masao | |||||
著者別名 | ||||||
姓名 | Miyake, Hitoshi | |||||
著者別名 | ||||||
姓名 | Ashida, Kan | |||||
著者別名 | ||||||
姓名 | Ichimura, Kenji | |||||
著者別名 | ||||||
姓名 | Watanabe, Kuniaki | |||||
著者別名 | ||||||
姓名 | Takeuchi, Toyosaburo | |||||
著者別名 | ||||||
姓名 | Kon, Shinji | |||||
著者別名 | ||||||
姓名 | Inoue, Teruaki | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | Clean-up Capability of an Emergency Detritiation System (II) | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | An emergency tritium removing system, using a precious metal/alumina catalyst, was designed and constructed in order to decontaminate tritium leaked accidentally into laboratory rooms. The performance of thee system was examined using a balloon for helium recovery or an aluminum vessel as a substitute of a laboratory room. Tritium gas containing about 10% tritiated methane (CH3T) as an impurity was introduced into the experimental room and then removed with an air flow rate of 72 m3/h. Tritium gas (T2) was removed satisfactorily, i.e. the reaction probability was unity, due to a Pd/Al2O3 catalyst (Nippon Jun Suiso Co. Ltd) at 200℃, while the tritiated methane could not be removed with a sufficient amount of efficiency: its reaction probability was below unity. It was found that the reaction probability of the tritiated methane became unity above 300℃ for this catalyst. On the basis of these results, it is estimated that the accidental leakage of tritium of 5Ci (which is the maximum permissible amount used in a day in this laboratory) into a laboratory room can be removed within an 18h period. | |||||
書誌情報 |
富山大学トリチウム科学センター研究報告 = Annual Report of Tritium Research Center, Toyama University 巻 2, p. 21-26, 発行日 1982 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0287-1408 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10100133 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 富山大学トリチウム科学センター | |||||
資源タイプ(DSpace) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article |